Problem

a. When more than three current-carrying conductors are installed in one raceway, their...

a. When more than three current-carrying conductors are installed in one raceway, their allowable ampacities must be reduced according to NEC_________.

b. The following is a project. We need four 15-ampere branch circuits. We will use two 3-wire multi wire branch circuits and 14 AWG THHN conductors. We will install the conductors in EMT. The room temperature will not exceed 86°F (30°C).

The connected load is non-motor and is non-continuous.

1. What is the minimum trade size EMT?_______________________________

2. What is the ampacity of the conductors before derating?

___________________________________________________________________________

___________________________________________________________________________

3. What is the ampacity of the conductors after derating?

___________________________________________________________________________

___________________________________________________________________________

4. What is the maximum overcurrent protection permitted for these conductors?

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

c. Let’s increase the conductor size to 12 AWG THHN for the same installation to see what happens.

1. What is the minimum trade size EMT?

___________________________________________________________________________

2. What is the ampacity of the conductors before derating?

___________________________________________________________________________

3. What is the ampacity of the conductors after derating?

___________________________________________________________________________

4. What is the maximum overcurrent protection permitted for these conductors?

___________________________________________________________________________

___________________________________________________________________________

d. It (is) (is not) necessary to count equipment grounding conductors, a neutral conductor that carries the unbalanced current from other conductors of the same circuit, and/or “travelers” when installing 3-way and 4-way switches for the purposes of derating the ampacity of these conductors. Circle the correct answer. Explain.

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

Step-by-Step Solution

Request Professional Solution

Request Solution!

We need at least 10 more requests to produce the solution.

0 / 10 have requested this problem solution

The more requests, the faster the answer.

Request! (Login Required)


All students who have requested the solution will be notified once they are available.
Add your Solution
Textbook Solutions and Answers Search
Solutions For Problems in Chapter 18