Problem

A 10-hp surface aerator was tested in a tank filled with 9200 ft3 of tap water at 22°C by...

A 10-hp surface aerator was tested in a tank filled with 9200 ft3 of tap water at 22°C by the non-steady-state procedure. The dissolved-oxygen saturation was assumed to be the stan­dard value of 8.8 mg/l from Table A. 10. Based on the following time and dissolved-oxygen data, determine the value of Kt a corrected to 20°C. Also calculate the oxygen transfer rate in pounds per horsepower-hour.

t (min)

Ct (mg/l)

t(min)

Ct  (mg/l)

0

0

8.0

5.5

2.0

3.0

11.0

6.3

4.0

4.3

14.0

7.1

6.0

5.0

17.0

7.6